Penggunaan Pitch Rendah pada Pemeriksaan CT Scan Kepala pada Kasus Trauma di RSUD Banyumas
DOI:
https://doi.org/10.57214/jka.v9i2.964Keywords:
Image Quality, Pitch, Radiologist, RSUD Banyumas, TraumaAbstract
RSUD (Regional General Hospital) Banyumas is a healthcare institution offering radiology services, such as head CT scans for trauma cases. The application of CT scan pitch parameters is essential for generating high-quality images while reducing the radiation exposure to the patient. This study employed a descriptive qualitative methodology utilizing a case study approach. The author presents an analysis of low pitch utilization in head CT scans for trauma cases at RSUD Banyumas. The research was carried out between May and June 2025. The participants included three radiographers and one radiologist. The methods employed for data collection comprised observation, interviews, and documentation. The study results demonstrate that the CT scan procedure for head trauma at RSUD Banyumas was executed with the patient in a supine head-first position and a pitch parameter set at 0.55. Employing a lower pitch enhances image detail and noise, although with the potential for increased radiation exposure. This study concludes that appropriate pitch utilization in head trauma CT scans at RSUD Banyumas significantly affects image quality.
References
Aditya, D., & Apriantoro, N. H. (2020). CT-scan kepala dengan klinis trauma kapitis post kecelakaan lalu lintas. KOCENIN Serial Konferens, 1(1), 1-7.
Bae, H., Lee, J. W., Jeong, Y. J., Hwang, M. H., & Lee, G. (2024). Increased scan speed and pitch on ultra-low-dose chest CT: Effect on nodule volumetry and image quality. Medicina (Lithuania), 60(8). https://doi.org/10.3390/medicina60081301
Bushberg, J. T., Seibert, J. A., Leidholdt, E. M., & Boone, J. M. (2012). The essential physics of medical imaging (3rd ed.). Philadelphia, PA: Lippincott Williams & Wilkins.
Bushong, S. C. (2021). Radiologic science for technologists: Physics, biology, and protection (12th ed.). Elsevier Health Sciences - Mosby. ISBN 10: 0323661343; ISBN 13: 978-0323661348.
Eddy, F. K., et al. (2021). Optimization of the scan length of head traumas on CT imaging. Scientific Reports, 11(1), 1-7. https://doi.org/10.1038/s41598-021-90529-4
Geçen, A., et al. (2024). Traumatic brain injury: CT imaging and cost-effectiveness. Advances in Radiology, 2024, 1-9. https://doi.org/10.1155/2024/54264
Kiragga, F., et al. (2023). Typical diagnostic reference levels of common CT procedures in Uganda. African Journal of Radiology, 21(1), 1-8. https://doi.org/10.4102/afrj.v21i1.228
Klod, D. P., Selatan, D., & Klod, D. P. (2024). Analisis hasil safire pada imaging CT scan kepala Irfan bersumber dari sinar-X dan dapat menampilkan gambar anatomi secara crossectional darurat dimana pasien mengalami cedera kepala, gejala stroke dan trauma pada. 2(3). https://doi.org/10.61132/corona.v2i3.604
Meißner, A.-K., et al. (2025). Evaluation of CT and MRI radiomics for an early assessment of diffuse axonal injury in patients with traumatic brain injury compared to conventional radiological diagnosis. Clinical Neuroradiology, 35(3), 521-532. https://doi.org/10.1007/s00062-025-01507-6
Ria Saputri, S., Angella, S., Salim, A., & Utama, J. (2023). Literatur review teknik pemeriksaan CT-scan kepala klinis cephalgia. JRI (Jurnal Radiografer Indonesia), 6(2), 93-97. https://doi.org/10.55451/jri.v6i2.222
Rizky, I., Putu, N., Jeniyanthi, R., Istri, C., Widiastuti, A., Radiodiagnostik, A. T., Radioterapi, D., & Penulis, I. K. (2024). Prosedur pemeriksaan CT scan kepala dengan klinis stroke hemorrhagic di RS Bhayangkara Makassar. Journal of Educational Innovation and Public Health, 2(1), 106. https://doi.org/10.55606/innovation.v2i1.2096
Sari, D., Setiawati, E., & Arifin, Z. (2020). Analisis nilai computed tomography dose index (CTDI) phantom kepala menggunakan CT dose profiler dengan variasi pitch. Berkala Fisika, 23(2), 42-48.
Shih, R. Y., et al. (2021). ACR appropriateness criteria® head trauma: 2021 update. Radiology, 299(2), 1-12. https://doi.org/10.1148/radiol.2021201878
Tan, W. S., et al. (2023). Investigating CT head diagnostic reference levels based on pitch parameters. Journal of Clinical Imaging Science, 13(1), 1-8. https://doi.org/10.25259/JCIS_69_2023
Wang, Y., et al. (2024). CT acquisition parameter selection in the real world. European Radiology, 34(5), 1-9. https://doi.org/10.1007/s00330-023-10161-w
Yunus, M., Wahyudi, A., Febriyani, A. H., Romizah, A., Radiologi RSU Daerah Pagar Alam Way Kanan, D. Z., Pendidikan Dokter, P., & Author, K. (2020). Karakteristik hasil CT-scan penderita cedera kepala di RS Dr. H. Abdul Moeloek 2018. ARTERI: Jurnal Ilmu Kesehatan, 1(3), 17. https://doi.org/10.37148/arteri.v1i3.56
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Jurnal Kesehatan Amanah

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.